Automated identification of potential pesticides residues in fruit samples using HRMS data

Automated identification of potential pesticides residues in fruit samples using HRMS data

70th ASMS Conference on Mass Spectrometry. June 2022

Elisabeth Ortega1; Ismael Zamora1; Pol Giménez1; Luca Morettoni1; Roberto Romero-gonzalez2; Rosalía Lopez-Ruiz2; Antonia Garrido Frenich2

1Lead Molecular Design, S.L., Sant Cugat del Valles, Spain; 2Research Group ‘Analytical Chemistry of Contaminants’, Department of Chemistry and Physics, Research Centre for Agricultural and Food Biotechnology (BITAL), Agrifood Campus of International Excellence, University of Almeria, Almeria, Spain

Abstract

Introduction

In food safety and related fields, High Resolution Mass Spectrometry techniques applied for multiresidue analysis had become an alternative to the historical routine procedures involving triple quadrupole instruments. This evolution was mainly driven by the possibility to interrogate hundreds or thousands of compounds without a prior individual study of all of them. However, due to the big amount of information that can be generated during the data acquisition, the later data processing and data analysis steps can be quite time demanding. In this presentation we will show how this late step could be automized using Chemical Monitoring workflow included in MassChemSite 3.1.

Methods

For chromatographic analysis, Thermo Fisher Scientific Vanquish Flex Quaternary LC (Thermo Scientific Transcend™, Thermo Fisher Scientific, San Jose, CA, USA) was used. The chromatographic system is coupled to a hybrid mass spectrometer Q-Exactive Orbitrap Thermo Fisher Scientific (ExactiveTM, Thermo Fisher Scientific, Bremen, Germany) using an electrospray interface (ESI) (HESI-II, Thermo Fisher Scientific, San Jose, CA, USA) in positive-negative mode. ESI parameters were as follows: spray voltage, 4 kV; sheath gas (N2, 95%), 35 (adimensional); auxiliary gas (N2, 95%), 10 (adimensional); S-lens RF level, 50 (adimensional); heater temperature, 305 °C; and capillary temperature, 300 °C.

Data processing has been done using MassChemSite 3.1 (Molecular Discovery, Ltd. Borehamwood, UK). Data analysis was performed in ONIRO server (Molecular Discovery, Ltd. Borehamwood, UK).

Preliminary data

Strawberry, white grape and orange samples providing from Almeria (Spain) greenhouses were acquired in the University of Almería and processed using the Chemical Monitoring data workflow included in MassChemSite 3.1. Data was interrogated against an in-house pesticide database generated by literature search including up to 1500 different pesticides. From the total, up to 10 different pesticides were detected in all the samples in less than five minutes of data processing.

The identification step was performed using the MS and MSMS information: MS was used to detect the pesticide in the sample, while fragmentation information was used to finally elucidate the structure of the detected pesticide, by means of a computational fragmentation of the detected pesticide and a later assignation to the MSMS data provided by the instrument. The fitting among computed and experimental fragments is reported as “score” which can be used to discriminate among other structural isobaric compounds associated to the same chromatographic peak.

Data analysis and reporting were done in ONIRO server after an automatic uploading of the raw data. Later filtering steps were applied and tracked by the application for further inspection. Additionally, a final report was generated automatically once the experiment was reviewed. Data generated during the acquisition remained on the server for later use or further re-analysis.

 

You must be logged in to access this content. Not yet registered? Create a new account

 

 

Oligonucleotides: degradation studies

Oligonucleotides: degradation studies

70th ASMS Conference on Mass Spectrometry. June 2022

Ismael Zamora1; Fabien Fontaine1; Tatiana Radchenko1; Bridget Becker2; Robert Greene2

1Lead Molecular Design, S.L., Sant Cugat del Valles, Spain; 2LabCorp Madison WI USA, Madison, WI

 

Abstract

Introduction

The study of the biotransformation products for therapeutic oligonucleotides using LC-MS is challenging issue due to the high molecular weight of this class of compounds. Since these compounds are composed of multiple monomers that can undergo metabolic reactions such as phosphodiester hydrolysis, this makes building the virtual set of all potential metabolites time and computational resource intensive. In addition, due to the high number of cleavable bonds, the fragmentation analysis requires even more time and computing power. Finally, there is a third challenge related to the depiction of the parent and the metabolites as atoms/bonds in a manner suitable for an algorithm to predict where in the molecule the metabolic reaction occurs.

Methods

New algorithms that address the challenges in highly modified therapeutic oligonucleotide structure elucidation have been developed. The peak detection algorithm was improved to use the Most Abundant Isotope for parent and potential metabolites. A new algorithm is producing all virtual metabolites applying the library of chemical reactions to each monomer while maintain the connection to the atoms. A third improvement it is the fragmentation algorithm that has two layers of analysis at monomer levels and the other at the bond levels. Finally, we will also show the results of the implemented algorithm for the analysis results visualization.

Preliminary data

The developed algorithm has been applied to a collection of experimental data for a set of oligonucleotides where the data was collected on a Q-Exactive instrument in negative ionization mode. The oligonucleotides have a molecular weight in the range of 7500 Daltons and contain 20 monomers that were a mixed of natural and non-natural nucleotides. Each construct was incubated in the presence of human or monkey liver homogenate for up to 72 hours to generate the metabolites for this project.

More than 10 biotransformation products were detected for each analyte with high mass accuracy (< 5 ppm). The majority of the metabolites resulted from one metabolic modification, but also compounds resulting from two biotransformations were detected by the new algorithm. Each of these compounds showed a suitable fragmentation pattern that could be compared to the parent by the fragmentation algorithm to assign the shifted and non-shifted fragments. For example, the most abundant metabolite accounted for 11.1 % of the total chromatogram area in one of the incubations, had an 0.16 ppm mass accuracy and had more than 120 fragments that could be used to identify its structure with a MassMetaSite score higher than 3322. The assigned structure corresponds to cleavage of the terminal nucleotide from the parent. The second most abundant metabolite had a mass accuracy of 0.60 ppm, a charge of minus 9, and over 100 assigned fragments yielding a MassMetaSite score of almost 5000.

 

You must be logged in to access this content. Not yet registered? Create a new account

 

AI (ARTIFICIAL INTELLIGENCE) applied to enhance the DMPK experimental efficacy

AI (ARTIFICIAL INTELLIGENCE) applied to enhance the DMPK experimental efficacy

70th ASMS Conference on Mass Spectrometry. June 2022

Ismael Zamora; Ramon Adàlia; Tatiana Radchenko

Lead Molecular Design, S.L., Sant Cugat del Valles, Spain

Abstract

Introduction

The goal of this presentation is to show multiple ways to increase DMPK experimental efficacy. An enhancement of efficacy in this context is understood as how to get more knowledge out of the data that is produced. This process is translated on how to decrease the time from data to compound design and/or how to increase the knowledge learned from the data. To achieve this objective automation of data processing, maximizing the extraction of information out of the data and the translation the newly acquired information into practical design is necessary.

Methods

To increase the automation a new methodology will be shown where the input experimental files acquired on a Thermo Q-Exactive instrument for a clearance workflow are processed without human intervention to obtain the clearance and metabolite identification results. The procedure will be exemplified in a collection of 20 PROTACS structures where the Clearance measurement in Hepatocytes has been performed. Clearance end point data computation will be shown together with the automatic fragment assignment for each of the metabolites.

Preliminary data

For example, the fragmentation observed and assigned for a particular compound was used to develop a model to predict the compound fragmentation. In this context several published spectra interpretation from the MoNA database have been used to determine a Machine Learning model to predict the probability of a bond to be broken under certain Mass Spectrometry condition. That publicly available information is used to derive a model that was validated and monitored by using the own experimental data generated in the automatic procedure mentioned before. Considering the result from the comparison between the experimental and the prediction values the new data was incorporated into an automatically learning process to improve model quality. In this way a self-learning system has been developed for the improvement of the virtual fragmentation of a compound.

The above self learning procedure was also applied for other Mass Spectrometry derived property like for example the Cross Collision section (CCS) value to assess the reliability of a structural assignment to a certain peak. In this case a regression model with a regression coefficient between the observed and the calculated CCS values of 0.98 was obtained after developing a model based on published data and enriched with our own dataset.

Finally, an example of how the metabolite identification information extracted from the previously described automation system is used to design compound with a reduction in compound clearance will be shown.

 

You must be logged in to access this content. Not yet registered? Create a new account

 

 

Automatic Quantification workflow using High Resolution Mass Spectrometry

Automatic Quantification workflow using High Resolution Mass Spectrometry

70th ASMS Conference on Mass Spectrometry. June 2022

Ismael Zamora1; Fabien Fontaine1; Pol Giménez1; Kevin P Bateman2; Christopher Konchansky2

1Lead Molecular Design, S.L., Sant Cugat del Valles, Spain; 2Merck & Co., Inc., Rahway, NJ, USA

Abstract

Introduction

Calibration lines in drug quantification workflows are traditionally determined using QQQ instruments that have high sensitivity and where the ion selectivity is gained by using multiple reaction monitoring. This workflow needs a previously identify transition to be monitored to obtain the needed selectivity for the compound of interest. In this work we demonstrate an automated methodology to perform quantification studies based on high-resolution mass spectra data. We obtain selectivity based on the high resolution, low ppm difference between the observed and the theoretical m/z computed from the compound formula. We gain the needed sensitivity by automatically considering multiple m/z ions, including adducts and fragments, in the computation of the peak areas.

Methods

The methodology has been developed using MSe data acquired on a Waters Xevo G2XS Qtof. A peak analysis is done in the high and low collision energy traces. The m/z of the each of the identified peaks in both MS functions are then compared to the m/z obtained for the parent molecular formula, the multiple charges, the adducts and/or the theoretically generated fragments. The list of experimental peaks that matches any of computed m/z is then submitted to the quality peak analysis (criteria: number of points/peak, ppm, signal/noise ratio, etc.). The area for each of the m/z is computed (isolated or in combination) using an auto-adjusting extraction window and later used in a regression analysis with multiple acceptance criteria.

Preliminary data

The data for the working example is obtained for a compound at 13 different concentration levels: 1, 2, 5, 10, 20, 50,1 00, 200, 500,1000, 2000, 5000, 10000 ng/mL measured in triplicate. The peak quality criteria were based on a minimum of eight scan points per peak, a difference in Retention Time between samples lower than 0.05 min, the ions with a difference between the observed and the computed m/z lower than 15 ppm.  The extraction window was auto-adjustable, the noise evaluation time range (peak units) was set to 6, a the Minimum signal/noise ratio to 3. The maximum variation of nominal concentration of each sample and the average, as well as the maximum CV was set to 25% for a point to be accepted for regression. For a line to be accepted a minimum number of concentration levels was set to 6 with a minimum replication of 2 and a maximum fold change between consecutive points was 10. Three lines can be derived to cover the wider dynamic range, the LLoQ and the ULOQ using different weighting factors. In the example that will be shown the best fragments for quantification are obtained even in absence of the M+H ion due to in-source fragmentation. The regression line obtained covered the dynamic range from 2 to 10000 with all the quality controls fulfilled with a combination of two m/z. It is also observed that due to the different ion intensity and noise evaluation for each ion it was necessary to perform an automatic optimization of parameter for the best peak quality.

 

You must be logged in to access this content. Not yet registered? Create a new account

 

 

Improving metabolite identification for complex peptides using MassMetaSite

Improving metabolite identification for complex peptides using MassMetaSite

70th ASMS Conference on Mass Spectrometry. June 2022

Ismael Zamora; Tatiana Radchenko; Fabien Fontaine; Albert Garriga

Lead Molecular Design, S.L., Sant Cugat del Valles, Spain

Abstract

Introduction

A commonly used strategy in the peptide therapeutics field to introduce chemical modifications such as cyclisation, changing the stereochemistry of an amino acid, substitution of natural amino acids to chemically modified ones and others to improve their efficacy and ADME profile. The study of the metabolic degradation products for synthetically modified therapeutic peptides using LC-MS is a challenging issue. Different chemoinformatics approaches are used for automated metabolite identification. These tools propose metabolite structures based on the combination of metabolite prediction and analysis of MS data. This makes building the virtual set of all potential metabolites time and computational intensive. Fragmentation analysis requires even more computation time. Finally, a third challenge related to the depiction of the parent and the metabolites.

Methods

New algorithms that address the challenges in highly modified therapeutic peptide structure elucidation have been developed. The peak detection algorithm was improved to use the Most Abundant Isotope for parent and potential metabolites. A new algorithm is producing all virtual metabolites applying the library of chemical reactions to each monomer while maintaining the connection to the atoms. A third improvement is the fragmentation algorithm that has two layers of analysis, one at the monomer level and the other one at the bond level. Finally, we will also show the results of the implemented algorithm for the analysis results visualization.

Preliminary data

Using MassMetaSite we analyzed a collection of experimental data for a set of peptides where the data was collected on a Q-Exactive Thermo instrument. The metabolite identification study was performed using a peptide set that included eight compounds: somatostatin and its seven synthetic analogues. All test compounds were incubated in serum. These peptides are all cyclic peptides and seven of them had unnatural amino acids. The structural assignments were performed for 17 degradation products with high mass accuracy (ppm<3). Most of the metabolites resulting from one or two metabolic modifications were produced by amide hydrolysis and were detected by the new algorithm. Each of these compounds showed a suitable fragmentation pattern that could be compared to the parent by the fragmentation algorithm to assign the shifted and non-shifted fragments. All the metabolites were checked manually including a review of the assigned fragments. Metabolites were considered as reliable because the fragmentation was adequate, isotope pattern was as expected, the small differences between the m/z of observed and theoretical, and the mass score was high. As previously reported in the literature, the first two most abundant metabolites with assigned structure correspond to cleavage of the linear part of the somatostatin. Finally, we analyzed experimental data for the insulin and semaglutide data where the data was collected on a Waters QToF. Insulin is a cyclic peptide that contains 3 disulfide bridges and semaglutide is a linear peptide that contains linkages and fatty acid. The visualization algorithm developed allows to show results for these complex structures in a such a manner that it is easy to interpret due to the constraint structure alignment between the substrate and the metabolite (keeping same orientation), a possibility to combine monomer and atom/bond notation. Therefore, the metabolic changes in the structure can be easily seen by the User.

 